BSFYM - ION EXCHANGE RESIN C-361

  • MSDS: BSFYM
  • Manufacturer: ALUMINUM CO OF AMERICA
  • Product Name: ION EXCHANGE RESIN C-361
  • National Stock Number: 6850-00N040869
Product Identification

Product ID:ION EXCHANGE RESIN C-361
MSDS Date:05/01/1990
FSC:6850
NIIN:00N040869
MSDS Number: BSFYM

Responsible Party
ALUMINUM CO OF AMERICA
181 THORN HILL RD
WARRENDALE, PA 15086-7527
US

Emergency Phone: 412-553-4000;800-424-9300(CHEMTREC)

Info Phone: 412-553-2881

Cage: 01634

Contractor
ALUMINUM CO OF AMERICA
472 ROCKDALE-FORMERLY IN PITTSBURG, PA, TX 76567 US

Telephone: 512-446-8461

Cage: 01634

Ingredients

SULFONATED COPOLYMER OF STYRENE & DIVINYLBENENE IN SODIUM

CAS: 69011-22-9

Fraction By Weight: 50-65%


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 35-50%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SOLID OR DUST MAY CAUSE EYE IRRITATION
OR CORNEAL INJURY DUE TO MECHANICAL ACTION.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE: FLUSH WITH A LARGE AMOUNT OF WATER FOR AT LEAST 15
MINUTES. GET PROMPT MEDICAL ATTENTION. SKIN: FLUSH WITH COPIOUS
AMOUNTS OF WATER. CALL MD . INHAL: REMOVE TO FRESH AIR. SUPPORT
BRTHG (GIV E O*2/ARTF RESP) . INGEST: CALL MD IMMED .

Fire Fighting

Extinguishing Media:USE WATER OR DRY CHEMICAL TO EXTINGUISH FIRES.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

Accidental Release

Spill Release Procedures:VACUUM/SWEEP UP AND TRANSFER TO CONTAINERS FOR
RECOVERY OR DISPOSAL. FLOOR MAY BE SLIPPERY; USE CARE TO AVOID
FAILS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AT AMBIENT TEMPERATURES. AVOID
REPEATED FREEZE-THAW CYCLES.
Other Precautions:DO NOT PACK COLUMN W/DRY ION EXCHANGE RESINS. DRY
BEADS EXPAND WHEN WET; THIS EXPANSION CAN CAUSE A GLASS COLUMN TO
SHATTER.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:USE WITH ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:SAFETY GLASSES AND/OR GOGGLES.
Other Protective Equipment:WEAR CLEAN, BODY-COVERING CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HAZ DECOMP:AGENTS CAN CAUSE EXPLOS TYPE RXN WHEN MIXED W/ION EXCHANGE
RESINS. PROPER DESIGN OF EQUIP TO PVNT RAPID BUILD-UP OF PRESS IS
NEC IF USE OF AN OXIDIZING AGENT SUCH AS NITRITE ACID IS CONTEMP
LATED. BEFORE USING STRONG OXIDIZING AGENTS IN CONT W/ION EXCHANGE
BEADS, CONSULT SOURCES KNOWLEDGABLE IN HNDLG MATLS.

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Vapor Pres:17@20C
Spec Gravity:1.3
Evaporation Rate & Reference:1(H*2O=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:LIGHT YELLOW TO AMBER BEADS, ODORLESS

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONT W/CONCENTRATED NITRIC ACID/ANY OTHER STRONG OXIDIZING
AGENTS. NITRIC ACID & OTHER STRONG OXIDIZING(SUPP DATA)
Stability Condition to Avoid:EXCESS HEAT (>90C,>194F).
Hazardous Decomposition Products:NAPHTHALENE, BENZALDEHYDES, PHENOL,
CARBON DIOXIDE, WATER, SULFUR OXIDES & ORG SULFONATES.

Disposal

Waste Disposal Methods:DISPOSE OF REISN IN LICENSED INDUSTRIAL WASTE
LANDFILL/BURN IN APPRVD INCIN ACCORDING TO LOCAL, STATE, & FEDERAL
REGS. FOR RESIN CONTAMD W/HAZ MATL, DISPOSE OF MIXT AS HAZ MATERIAL
ACCORDING TO LOCAL, STATE, AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.